Ashcroft DG25 General Purpose Digital Gauge Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Ashcroft DG25 General Purpose Digital Gauge. Ashcroft DG25 General Purpose Digital Gauge User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com
All sales subject to standard terms and conditions of sale.
© 2012 Ashcroft Inc. I&M006-10197 DG25
Software Version 1.00.00
Installation and Operating
Instructions for General
Purpose Digital Pressure
Gauge Type DG25
DG25 I&M Rev. #2_I&M006 10197 7/30/12 11:41 AM Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Gauge Type DG25

1Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com All sales subject to standard terms

Strona 2

10Light: Determines how long the back light will remainON after any key is pressed in Measurement orMenu Modes (Note: The timer is reset with anykey b

Strona 3

11Z-Lock: Utilized to prevent inadvertent re-zeroing of theinstrument. 1. In Menu mode, press , ➟until“ZLOCK” appears.2. Press ||➟to select.3.

Strona 4

128. Display flashes “APPLY/ REF/ PSI/ THEN/PRESS/ ENTER/ TO/ START/ OR/ OTHER/TO/ ABORT”; apply the pressure indicatedin numeric display to gauge and

Strona 5

136. To program minimum graph percentage,the display will indicate 0 0 with the rightdigit flashing, the bottom most segmentof the bar graph will fla

Strona 6

14Changing Batteries: Grip knurled back cover and rotate counter-clockwise until the ‘unlock’ icon is in alignmentwith the arrow – this is on the hous

Strona 7

1527mm1.063inHex67mm2.64in50.5mm1.99in69.36mmØ2.73in1/4 NPT MaleØ 40.9mm1.61in67.6mm2.66in17.5mm.69inPressure Range:ProofPressure: Vac-2000psi 200%

Strona 8

#Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USATel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com All sales subject to standard terms

Strona 9

2DG25 I&M Rev. #2_I&M006 10197 7/30/12 11:41 AM Page 2

Strona 10

(if possible), pumps should be brought up topower slowly, and valves opened slowly. Toavoid damage from both fluid hammer andsurges, a surge chamber s

Strona 11

44. GENERAL INFORMATION:Keypad: Power On-Off / Enter ||Zero / Up Arrow / TareZERO TareMenu Selection / Down / Backlight Arrow MENU  Key pr

Strona 12

5LCD DISPLAY:LCD functions: 5 numerical digits for pressure display. 20 segment pressure range bar graph – each segment equals 5% of range.

Strona 13

6Note: Key presses designated as short (lessthan 0.5 sec) are indicated by “➟” ICONKey presses designated as long (greater than0.5 sec.) are indicate

Strona 14 - ASME B40.100

7Tare Function:Subtracts current pressure value from valuedisplayed in Measurement mode. In Measurement mode, apply desired pressurepress ZERO ➟, to

Strona 15 - Dimensions:

Custom Units of MeasureAllows a user to define a custom unit of meas-ure, user must enter the full scale value of thedesired reading, which can be don

Strona 16

9Timer: Controls how long the gauge will remain pow-ered ON once the Power key ||is pressed.1. When in menu mode press , ➟to scroll until “TIME